Synchronous Motor-for Sintering Fan Blast Furnace Fan, Water Pump T1120-4 25000kw 6kv

Motors are  often employed to generate tools these kinds of as blast furnace followers and sintering fans in the metallurgical industry
I. Overview
T collection big-scale three-stage four-pole, 6-pole synchronous motor and so forth are series of goods developed by our organization on the foundation of introducing and absorbing innovative technological innovation at residence and overseas. It is commonly employed in petroleum, chemical, electric powered electricity and other industries, and is utilized to travel high-inertia mechanical masses this kind of as followers, pumps, and compressors.
This sequence of motors adopts new technology, new components, new procedures, exquisite materials selection, advanced manufacturing, modest measurement, light excess weight, high effectiveness, reduced noise, low vibration, risk-free and reputable operation, and practical use and servicing.
Two implementation specifications
GB755 Rotating Motor Rating and Overall performance
CZPT problems of JB/T2224 large AC a few-section 4-pole synchronous motor
GB/T1571 Three-section synchronous motor test method
GB/T997 motor structure and installation type code
GB/T1993 Rotating Device Cooling Strategy
GB/T4942.one Motor shell defense grade
GB/T10068 Rotating motor vibration measurement strategy and restrict
GB/T10069 Rotating Device Noise Measurement Strategy and Restrict
three. Basic technical parameters
Power selection: 400~40000KW
Voltage: 6000, 10000V
Speed: a thousand, 1500r/min
Rated frequency: 50HZ
Defense stage: IP44, IP54
Insulation course: F
Quota: S1
Cooling method: IC81W, IC91W
Installation strategy, IM1001
*Can be produced according to other parameters according to consumer requirements
Four, technological characteristics
4.one By adding a “Γ”-formed damping ring to the reliable magnetic poles, the motor can give a large ample starting torque, a pulling torque and a decrease starting up current, which can make certain the smooth starting up and acceleration of the motor, and have a modest influence on the electrical power grid, and meet up with the user load specifications .
4.two The use of new insulating supplies and insulation technologies, with tremendous robust insulation and voltage resistance.
4.three The motor adopts course F insulation, and the temperature rise is assessed according to the temperature rise limit price of course B insulation. It has a long service lifestyle and a great air flow method, which tends to make the device under numerous operating conditions such as startup, overload, overexcitation, underexcitation, and shutdown. Make certain that the temperature increase of every element does not exceed the allowable limit.
4.4 Via exact calculation and evaluation, the construction of the rotor is established. The higher-energy motor adopts the integrated construction engineering of shaft and choke to make the motor protected and reputable.
four.5 The protection device is innovative and full.
4.five.one The stator windings and bearings are equipped with temperature detection gadgets, which can detect, alarm and journey.
4.five.two Shutdown area heater with anti-condensation effect.
5, construction type
5.one The composition of this sequence of motors is typically horizontal, and the cooling method is a shut circulating air cooling system, which is situated at the bottom of the motor. For further-large-electrical power motors, it is of box-type framework and water-cooled.
five.2 The motor magnetic content adopts high-high quality chilly-rolled silicon metal sheet with substantial magnetic permeability and lower reduction, which enhances the functioning performance of the motor and minimizes the working value of the motor. Rigid stator construction, the iron main is fastened on the supporting ribs of the frame in the circumferential path by way of the dovetail groove and compressed in sections with high pressure, and all the forces are transmitted to the base via the body, reducing vibration. The damping ring and the magnetic pole adopt a specific fixing technique to avoid malfunctions induced by bad contact all interior conductive body connectors, fasteners, supports and screws on the rotating physique have anti-loosening measures to make sure firmness and trustworthiness.
5.3 The stator winding is dealt with with VPI as a whole dipping paint, which has higher electrical efficiency, mechanical power, insulation efficiency, dampness resistance and thermal stability.
5.four The bearing is a sliding bearing with pressure oil circulation, which is set up in a bearing seat manufactured of solid steel. The sliding bearing has a spherical bearing that can instantly change the heart. The interior surface of the bearing is coated with a layer of Babbitt alloy to prevent power generation Direct-tin eutectic takes place when the machine is managing at large temperature. The bearings are insulated to avert shaft currents.
6. Conditions of Use
six.1 Voltage fluctuation: ±5% (It can operate at ±10% beneath the problem of 7.three in GB755).
6.2 Frequency fluctuation: ±2%.
six.3 The altitude does not exceed 5000m
6.4 The greatest ambient air temperature does not exceed +50ºC,
six.five The inlet temperature of the cooling water of the air cooler should be stored in the range of 6~33ºC, the pressure of the cooling water is .3Mpa, and the cooling h2o must have no corrosion effect on copper and iron.
six.6 If the earlier mentioned standard situations of use are exceeded, corresponding steps or particular orders should be taken.
7, model description
Motor with composition form IM7311: Motor with structure kind IM1001
T7000-four/1730T1120-415000KW

Outer diameter of stator core (Φ1730mm) Rated electricity (15000KW)

Amount of poles (4 poles) Quantity of poles (4 poles)

Rated electricity (7000KW) Centre height (1120mm)

T series synchronous motor T series synchronous motor
8. Ordering directions
8.1 Prior to placing an purchase, remember to refer to the item catalog of this sequence to make clear the essential merchandise product, requirements and other knowledge. If there is any discrepancy among the essential kinds and technical specs, please make contact with our business.
eight.two When buying, the motor product, rated energy, pace, rated voltage, rated frequency, security amount, load minute of inertia, rotation route, set up kind, etc. must be indicated.
eight.three The technical info sheet in the catalog only lists the relevant knowledge of motors with rated voltages of 6KV and 10KV. If consumers demand other voltage stages, our company can also give complex info when buying.
eight.4 The technological information and proportions in the sample are only for reference when end users choose designs. The formal details will be offered by the organization after the contract or technological arrangement is signed.
eight.5 If you have any other unique requirements, this kind of as brushless excitation, variable frequency start off, etc., make sure you offer the demands and sign the related technological agreement when buying.
 
 

Synchronous Motor-for Sintering Fan Blast Furnace Fan, Water Pump T1120-4 25000kw 6kv